SAN DIEGO COUNTY AIR POLLUTION CONTROL DISTRICT
RULE 260.455 - REPORTING AND RECORDKEEPING REQUIREMENTS
(Rev. Effective 11/3/92)
(a) The reporting requirements of Rule 260.8(a) apply only to the initial performance test. Each owner or operator
subject to the provisions of this subpart shall include the following data in the report of the initial performance
test required under Rule 260.8(a):
(ii) The VOC reduction efficiency of the control device (E).
(iii) The average combustion temperature (or the average temperature upstream and downstream of the catalyst bed), and
(iv) A description of the method used to establish the amount of VOC's captured and sent to the incinerator.
(i) The volume of VOC-solvent recovered (Lr), and
(ii) The overall VOC emission reduction achieved (R).
(b) Following the initial performance test, the owner or operator of an affected facility shall identify, record, and submit a written report, as specified in Rule 260.7(c), to the Control Officer every calendar quarter of each instance in which the volume-weighted average of the total mass of VOC's emitted to the atmosphere per volume of applied coating solids (N) is greater than the limit specified under Rule 260.452. If no such instances have occurred during a particular quarter, a report stating this shall be submitted to the Control Officer semiannually.
(c) Following the initial performance test, the owner or operator of an affected facility shall identify, record,
and report semiannually to the Control Officer the following:
(d) Each owner or operator subject to the provisions of this subpart shall maintain at the source for a period of at least two years, records of all data and calculations used to determine VOC emissions from each affected facility. Where compliance is achieved through the use of thermal incineration, each owner or operator shall maintain at the source daily records of the incinerator combustion chamber temperature. If catalytic incineration is used, the owner or operator shall maintain at the source daily records of the gas temperature, both upstream and downstream of the incinerator catalyst bed. Where compliance is achieved through the use of a solvent recovery system, the owner or operator shall maintain at the source daily records of the amount of solvent recovered by the system for each affected facility.