Previous
Executive Orders have been modified to include wording allowing
retrofit installations on equipment that have undergone fuel
conversions. New Executive Orders are posted
below.
Please
read the verification Executive Orders and attachments below which
provide additional information on the applicability of the device for
your particular engine. For more detailed information or to purchase
the device, please contact the device manufacturer directly.
New
information will be posted as additional systems are verified. Please
check periodically for updates. |
|
| This Executive Order supersedes
previous EXECUTIVE ORDER G-07-019 |
EXECUTIVE ORDER G-08-007
Attachment - Label
|
|
Executive Order Date
|
Level 3a
|
Manufacturer
|
Emission Control System
|
| 6/16/2008 |
1.3g/kW-hr of NOx and HC 1.0
g/bhp-hr of NOx and HC
|
Engine
Control Systems |
TermiNOx™ |
|
| The TermiNOx™ emission control
system for Engine Control Systems. The TermiNO™system employs
engine management diagnostics controllers with closed-loop catalytic
control of nitrogen oxides, hydrocarbon and carbon monoxide to achieve
emission reductions qualifying it as a
Level 3a verification for use on uncontrolled large spark ignited
equipment.
An emission control family name: CA/2005/ECS/LL3a/NH1.0/OFF/SYS01 is to
be on labels affixed to the catalyst and the engine control unit. For
more detailed information or to purchase the device, please contact the
device manufacturer directly (enginecontrolsystems.com). |
|
| This
Executive Order supersedes previous Interim Verification Letters. |
| EXECUTIVE
ORDER G-07-019 |
|
Executive Order Date
|
Level 3a
|
Manufacturer
|
Emission Control System
|
| 6/25/2007 |
1.3g/kW-hr of NOx and HC 1.0
g/bhp-hr of NOx and HC
|
Engine Control
Systems |
TermiNOx™
|
|
|
|
This Executive Order supersedes
previous EXECUTIVE ORDER G-07-018
|
EXECUTIVE ORDER G-08-005
Attachment - Label
|
|
Executive Order Date
|
Level 3a
|
Manufacturer
|
Emission Control System
|
| 6/16/2008 |
2.0g/kW-hr of NOx and HC 1.5
g/bhp-hr of NOx and HC
|
Nett
Technologies Inc. |
Nett® BlueCAT
200™
|
|
| The Nett® BlueCAT 200™ system maintains optimal air /
fuel ratios at all engine-operating conditions and maximizes the
three-way catalyst for emission reductions of nitrogen oxides,
hydrocarbon and carbon monoxide. An emission control
family name CA/2006/NET/LL3a/NH1.5/OFF/SYS01 is to be on labels affixed
to the catalyst and the engine. The
emissions are reduced qualifying it as a
Level 3a verification for use on uncontrolled large spark ignited
equipment. Specific
conditions for which the Nett® BlueCAT 200™ was approved can be found
in the Executive
Order G-07-018. For detailed
information or to purchase a system, please contact the manufacturer
directly (nett.ca). |
|
| This
Executive Order supersedes previous Interim Verification Letters. |
| EXECUTIVE ORDER G-07-018 |
|
Executive
Order Date
|
Level 3a
|
Manufacturer
|
Emission Control
System
|
| 6/25/2007 |
2.0g/kW-hr of NOx and HC 1.5
g/bhp-hr of NOx and HC
|
Nett
Technologies Inc. |
Nett® BlueCAT
200™
|
|
|
|
| This Executive Order supersedes
previous EXECUTIVE ORDER G-07-017 |
| EXECUTIVE ORDER
G-08-006
Attachment - Label |
|
Executive Order Date
|
Level 3a
|
Manufacturer
|
Emission Control System
|
| 6/16/2008 |
1.3g/kW-hr of NOx and HC 1.0
g/bhp-hr of NOx and HC
|
Nett
Technologies Inc. |
Nett® BlueCAT
300™
|
|
| It is appropriate for use on transient and
constant speed applications. The system maintains optimal air / fuel
ratios at all engine-operating conditions and maximizes the
three-way catalyst for emission reductions of nitrogen oxides,
hydrocarbon and carbon monoxide. An emission control family name:
CA/2007/NET/LL3a/NH1.0/OFF/SYS01 is to be on labels
affixed
to the catalyst and the engine. The emissions are reduced qualifying it as a Level 3a
verification
for use on uncontrolled large spark ignited equipment.
Specific conditions for which the Nett® BlueCAT 300™
has been approved can be found in the Executive Order G-07-017. For
detailed information or to purchase a system, please contact the
manufacturer directly (nett.ca). |
|
| EXECUTIVE
ORDER G-07-017 |
|
Executive Order Date
|
Level 3a
|
Manufacturer
|
Emission Control System
|
| 6/1/2007 |
1.3g/kW-hr of NOx and HC 1.0
g/bhp-hr of NOx and HC
|
Nett
Technologies Inc. |
Nett® BlueCAT
300™
|
|
|
|
| This
Executive Order supersedes previous EXECUTIVE ORDER G-07-066 |
| EXECUTIVE ORDER G-08-008
Attachment - Label |
|
Executive Order Date
|
Level 2
|
Manufacturer
|
Emission Control System
|
| 6/16/2008 |
4.0 g/kW-hr 3.0 g/bhp‑hr
|
Engine Control Systems |
TermiNOx™
|
|
| The TermiNOx™ emission control system from Engine Control Systems for
use on
uncontrolled equipment applications sizes greater than 3.0 liters up to
8.2
liters that meet the criteria listed in the Executive Order. The TermiNOx™ emission
control system employs
engine management diagnostics controllers with closed-loop catalytic
control of
nitrogen oxides, hydrocarbon and carbon monoxide to achieve emission
reductions qualifying it for
Level 2
verification. Specific conditions for which the TermiNOx™ has been
approved may
be found in the Executive Order G-07-066. For more detailed information or to purchase the device, please
contact
the device manufacturer directly (enginecontrolsystems.com). |
|
| EXECUTIVE ORDER G-07-066 |
|
Executive
Order Date
|
Level 2
|
Manufacturer
|
Emission
Control System
|
| 11/1/2007 |
4.0 g/kW-hr 3.0 g/bhp‑hr
|
Engine Control Systems |
TermiNOx™
|
|
|