AMAAPCD RULE 306 BURN PLAN
LAST REVISED 11/11/11

Rule 306  Burn Plan

     306.1.    Prohibition.  No person required to comply with
               the provisions of this Rule shall knowingly permit
               open outdoor fires that do not meet the following
               requirements.

     306.2.    Requirements.  The following information shall be
               provided to the APCO for review and approval at
               least twenty (20) days in advance of the proposed
               burn:

               A.   Location and specific objectives of the
                    proposed burn.

               B.   Acreage or tonnage, type, and arrangement of
                    vegetation to be burned.

               C.   Directions and distance to nearby sensitive
                    receptor areas.

               D.   Fuel condition, and combustion and
                    meteorological prescription elements 
                    developed for the project.

               E.   Projected schedule and duration of project
                    ignition, combustion, and burndown.

               F.   Specifications for monitoring and verifying
                    critical project parameters.

               G.   Specification for disseminating project
                    information.

               H.   Other information as requested or required by
                    the APCO or other agencies.