NORTH COAST UNIFIED AIR QUALITY MANAGEMENT DISTRICT
SECTION II
HEXAVALENT CHROMIUM CONTROL FROM CHROME PLATING
AND CHROMIC ACID ANODIZING FACILITIES
RULE 2-400 - HEXAVALENT CHROMIUM CONTROL FROM CHROME PLATING AND CHROMIC ACID ANODIZING FACILITIES
(a) REQUIREMENTS FOR DECORATIVE CHROME PLATING FACILITIES
- No person shall operate a decorative chrome plating tank unless an anti-mist additive is continuously maintained
in the plating tank, or control equipment is installed and used, in a manner which has been demonstrated to and
approved by the District Air Pollution Control Officer as reducing chromium emissions by 95 percent or more relative
to chromium emissions when an anti-mist additive is not maintained, or control equipment is not installed and used.
(b) REQUIREMENTS FOR HARD CHROME PLATING AND CHROMIC ACID ANODIZING FACILITIES
- The owners or operators of all hard chrome plating and chromic acid anodizing facilities shall maintain a continuous
record of current integrated over time (ampere-hours) for all plating tanks for each collection system used in
the hard chrome plating or chromic acid anodizing operations and shall, within six months after district adoption
of regulations enacting this control measure, and upon request thereafter, submit the information to the District
Air Pollution Control Officer.
- No person shall operate a plating tank for hard chrome plating or chromic acid anodizing unless the tank has
an emissions collection system whose design and whose operational parameters are approved by the Air Pollution
Control Officer.
- No person shall operate a hard chrome plating or chromic acid anodizing tank at a facility if facility-wide
chromium emissions from hard chrome plating or chromic acid anodizing are less than 2 pounds per year, unless:
- the chromium emissions from the emissions collection system serving the plating tank have been reduced by 95
percent or more of the uncontrolled chromium emissions or
- the chromium emissions from the emissions collection system serving the plating tank have been reduced to less
than 0.15 milligrams (mg) of chromium per ampere-hour of electrical charge applied to the plating tank.
- No person shall operate a hard chrome plating tank or chromic acid anodizing tank at a facility if facility-wide
chromium emissions from hard chrome plating or chromic acid anodizing are greater than 2 pounds per year, but less
than 10 pounds per year, unless
- the chromium emissions from the emissions collection systems serving the plating tanks have been reduced by
at least 99 percent of the uncontrolled chromium emissions from the hard chrome plating or chromic acid anodizing
facility or
- the chromium emissions from the emissions collection systems are reduced to less than 0.03 mg of chromium per
ampere-hour of electrical charge applied to the tanks.
- No person shall operate a hard chrome plating or chromic acid anodizing tank at a facility if facility-wide
chromium emissions from hard chrome plating or chromic acid anodizing are 10 pounds per year or greater, unless;
- the chromium emissions from the emissions collection systems serving the plating tanks have been reduced by
at least 99.8 percent of the uncontrolled chromium emissions from the hard chrome plating or chromic acid anodizing
facility or
- the chromium emissions from the emissions collection systems are reduced to less than 0.006 mg of chromium
per ampere-hour electrical charge applied to the tanks.