Comment Log Display

Here is the comment you selected to display.

Comment 26 for ShorePower (shorepwr07) - 45 Day.

First NameLarry
Last NameHottenstein
Email Addresslarry.hottenstein@erm.com
AffiliationERM
SubjectComment on Emission Measurement Method
Comment
The emission measurement method for diesel PM for demonstrating
control efficiencies for alternative control technologies
(f)(4)(B)3. should allow CARB Test Method 5 or U.S. EPA Reference
Method 5 and 202.  The ISO 8178 Test Methods needlessly require a
dilution tunnel, 5 stable test modes, and a different temperature
(125 F) defining PM.  Auxilliary engine exhaust stack diameters
and gas velocity are normally within the range to allow standard
isokinetic PM sampling.  Accepted CARB standard methods should be
utilized to provide consistency in PM measurements.

Attachment
Original File Name
Date and Time Comment Was Submitted 2007-12-05 14:46:41

If you have any questions or comments please contact Clerk of the Board at (916) 322-5594.


Board Comments Home