Semi-Volatile Compounds
Substance (Polycyclic Aromatic Hydrocarbons):
Benzo(a)pyrene
Benzo(b)fluoranthene
Benzo(g,h,i)perylene
Benzo(k)fluoranthene
Dibenz(a,h)anthracene
Indeno(1,2,3-cd)pyrene
Collection Method:
SSI-equipped high volume sampler
Quartz fiber filter
Laboratory Instrument:
High Performance Liquid Chromatography
Laboratory Detector:
Fluorescence Detector
Particulates
Substance (HiVol Metals):
Arsenic (2000 and earlier)
Beryllium (California: 1993 and earlier)
Beryllium (Mexico: 1998 and earlier)
Cadmium (1996 and earlier)
Collection Method:
High volume sampler
Glass fiber filter
Laboratory Instrument:
Graphite Furnace Atomic Absorption
Spectrophotometer
Laboratory Detector:
Photomultiplier Tube
Substance (Hexavalent Chromium):
Hexavalent Chromium
Collection Method:
Xontech920/Teflon filter
Laboratory Instrument:
Ion Chromatography
Laboratory Detector:
UV/Vis Detector
Substance (LoVol Metals):
Aluminum
Antimony
Arsenic (2001 and later)
Barium
Beryllium (2013 and later)
Bromine
Cadmium (2007 and later)
Calcium
Chlorine
Chromium
Cobalt
Copper
Iron
Lead
Manganese
Mercury
Molybdenum
Nickel
Phosphorus
Platinum
Potassium
Rubidium
Selenium
Silicon
Strontium
Sulfur
Tin
Titanium
Uranium
Vanadium
Yttrium
Zinc
Zirconium
Collection Method:
Xontech920/Teflon filter
Laboratory Instrument:
X-ray Fluorescence
(February 2003 and earlier, 2008)
Inductively Coupled Plasma -
Mass Spectrometer
(after February 2003 except 2008)
Laboratory Detector:
Solid-State Lithium-Drifted Silicon Detector
(February 2003 and earlier, 2008)
Electron Multiplier